APL 8016 DAU Detailed Specification General Features
• 8 channels
• Each channel can be used as either analogue or frequency input
• Up to 75 Hz sampling rate
• Synchronised sampling on all channels
• Separate excitation circuit for each channel
• Fully compatible with T-MON software
Input Specification
• 8 channels with simultaneous sampling
• Each channel can be used as either frequency or analogue input
• IP66 circular connectors (option of screw or sprung terminals)
• Differential inputs
• >5000 MΩ input impedance
• 50 V continuous maximum safe input
• 100Ω internal 0.1% precision sense resistor for current loop signals
Analogue Channel Specification
• Programmable gain for each channel up to 8000 (calibrated for gains up to 1000)
• 16 gain settings from product of [ 1 2 4 8 ] and [ 1 10 100 1000 ]
• 0.1% of full scale accuracy
• ±5 V range programmable offset for each channel
• 3 mV resolution
• 0.1% of full scale accuracy
• Temperature drift 0.2 mV/°C
• Programmable anti-aliasing filter
• 5 to 50 Hz range, set collectively for all channels
• 5th order Bessel filter
• Amplifier temperature drift
• 30 ppm/°C of gain (k=1), -100 ppm/°C of gain (k=1000)
• 0.01 mV/°C offset (k=1), 0.6 mV/°C offset (k=1000, at output)
• Better than 0.1 % linearity
• Better than -90 dB common mode rejection ratio
• Better than -100 dB cross talk between any channel
• <0.01% rms of full scale noise level (gain1000)
Analogue to Digital Converter
• 16 bit resolution
• ±10 V range. Full dynamic range available for gains up to 1000
• Sample and hold for each channel
Frequency Inputs
• Maximum frequency 2 kHz
• 5 to 36 V input pulses
• Schmidt trigger. Max On Voltage = 4.2V, Min Off Voltage =0.9V
• Accuracy better than 0.05 %
• Full scale range specified by user (1 to 2000 Hz)
• Resolution 15 bit over user specified range
• Transient protection on all connections
• -10 to 50 °C temperature operating range
• Temperature stability 10 ppm
Excitation Supply
• Programmable regulated voltage for each channel from 2.5 to 10 V, up to 55 mA
• ±0.1 % accuracy
• 3 mV resolution
• Excitation Temperature Drift 0.2 mV/°C
• 12 V unregulated mode, up to 55 mA per channel
• Short circuit protection, maximum current 80 mA per channel
• 24V unregulated supply available on connector (fused at 0.5 A for all channels)
Computer Interface
• RS232 or RS422 at 19,200 Baud
• Half duplex
• Synch pulse (if used)
Modes of Operation
• Sample from external pulse
• Sample from byte command
• Sample from internal clock
Configuration
• All settings programmable via serial interface
• Protocol provided
• All settings are retained after power loss
• Can be used as rotor speed and position unit with change of EPROM
Miscellaneous
• Internal temperature and voltage checks
• Self check at power up
• LED indicators for Power, Transmit, Receive and Synch Pulse
Power Requirements
• Input voltage range 18-36V DC
• Maximum VA (excitation circuits not used) 13 VA
• Maximum VA (all excitation circuits at full load) 17.5 VA
• Fully isolated internal supplies
• Self resetting fuse protection
• Reverse polarity protection
Physical & Environmental
• 270 mm long, 130 mm wide, 65 mm high (excluding connectors)
• 3.4 kg weight
• IP66 enclosure
|
|